Dongguan Yuyang Instrument Co., Ltd.
jackson.sun@yuyangtest.com
YUYANG original company logo
YUYANGTesting & Heating Solutions
Request a quote
Oil Analysis Equipment

ASTM D92 Cleveland Open-Cup Flash Point Tester

Select a laboratory instrument around the oil sample and the property your method measures.

Model COC-H4

Place of Origin
CHINA
Brand Name
YUYANG
Model Number
COC-H4

Your inquiry will include this product. Add your application and required configuration for a specific proposal.

ABOUT THIS EQUIPMENT

Product overview

Published listing name

ASTM D92 Cleveland Open Cup Flash Point Test Instrument With Manual Operation

This instrument is suitable to determine flash point and fire point of petroleum products.

Principle :fill the sample into sample cup with mark line.Firstly raise sample temperature quickly,then gradually.When near to flash point,constantly raise temperature.According to specified temperature interval,using small fire cross the sample cup,take the minimum temperature of steam flash on surface of sample as flash point.

StandardGB/T3536,ASTM D92,ISO2592
Power SupplyAC( 220±10% )V, 50 Hz.
Heating Power0~800W Adjustable

Application & operating notes

  • Complete sealed structure can avoid the influence of natural wind to test result.

MODEL INFORMATION

Technical specifications

StandardGB/T3536,ASTM D92,ISO2592
Power SupplyAC( 220±10% )V, 50 Hz.
Heating Power0~800W Adjustable
DisplayDigital
Warranty1 Year
ColorBlack
OperationManual
Product NameCleveland Open Cup Flash Point Test Instrument

Additional technical data

1Applicable standardsGB/T3536,ASTM D92,ISO2592
2Heating methodsealed stove,imported heating wire
3Temperature adjusting methodimported solid regulator
4Scanning methodautomatic scanning and igniting
5Heating power0~800W adjustable

Technical information is transcribed from the published product listing. Confirm the final model, test method edition and supplied configuration before ordering. Listing a standard does not establish third-party certification.

MODEL & QUOTATION ESSENTIALS

Check the fit for your application.

Published model: COC-H4 · Listing reference: 11192051

Test methodConfirm with YUYANGNot published in the available specification
Test standardConfirm with YUYANGNot published in the available specification
Temperature rangeConfirm with YUYANGNot published in the available specification
Measuring rangeConfirm with YUYANGNot published in the available specification
Power supplyAC( 220±10% )V, 50 Hz.Published value
Included items and options to confirm

Ask the quotation to separate the base equipment, included accessories, optional items and customer-supplied utilities. This page does not confirm that everything shown in a photograph is included.

  • Application and specimen details
  • Required method, range and measurement accuracy
  • Accessories and installation utilities
Request model data & configuration

SELECT YOUR CONFIGURATION

Start with your application.

Share these details so we can review this equipment against your project.

Oil sample and property to be measured

Describe the sample or application; a drawing or photograph can help clarify the requirement.

Test method, range and sample volume

State your required values and method edition, where applicable.

Consumables, accessories and laboratory utilities

Identify the setup you need; ask us to confirm compatibility and the supplied scope.

Agree what is supplied before ordering

Request an itemized proposal covering the exact model, required fixtures or accessories, available documentation, installation requirements and delivery terms. This is a confirmation checklist, not a claim that every item is included.

Discuss this configuration

BEFORE YOU REQUEST A QUOTE

Questions & product documents

Product photographs & configuration

Selected original equipment photographs · Click to enlarge

Photographs do not define the supplied accessories. Ask for current, same-model photographs and confirm the included items in the written proposal.

View unprocessed source photograph
Which model and accessories will be included?

The published model reference is COC-H4. Confirm fixtures, probes, software, consumables and other accessories in the written quotation. Items visible in a photograph are not automatically included.

Will it meet my test method or application?

Send the full method number and edition, the specimen or workpiece details, and your required operating range. The technical proposal should state the supported method and agreed setup for your project.

Can I review more technical information?

Download the product brief below for the information currently published on this page. You can also request a model-specific data sheet, demonstration video, manuals and installation requirements. Availability should be confirmed with the team.

How do I confirm pricing, lead time and shipping?

Provide the destination and required quantity. Request a current quotation covering the agreed configuration, packing, delivery terms and support scope.

Product & specification brief

Save this page’s published facts and source reference for your technical review.

ASTM D92 Cleveland Open Cup Flash Point Test Instrument With Manual Operation — prepared supplier photograph